Software Engineering · Posted 7d ago
Principal Condition Monitoring Engineer – Power Generation - Data Center Infrastructure (on-site Nashville, TN)
$205k – $265k
Oracle doesn't publish pay for this role. This is the middle half of base pay across 2,705 US Software Engineering Staff / Principal roles that do. See the benchmark
Opens Oracle's official careers page. Checked just now.
- Open to applicants in
- North America
- Base Salary
- Not published
- Listing status
- Live on the careers page
Requirements and tooling
Estimated from the role type. The posting doesn't name these:
>>This position will be full-time on-site at Oracle's offices located in Nashville, TN. Relocation assistance may be available in accordance with Oracle’s relocation policies. Candidates should expect a minimum of 25% travel, with additional travel as business needs require.<<
The Condition Monitoring Engineer leads condition monitoring and predictive maintenance for power plants and utility substation equipment to improve reliability, availability, and asset life. The role requires 6-10+ years of relevant experience in power plant monitoring, including gas turbines, reciprocating generators, diesel and natural-gas generation, associated alternators, and balance-of-plant systems.
This engineer combines field inspections, online monitoring, diagnostic testing, and operating-data analysis to detect deterioration, assess equipment health, and recommend timely maintenance. The role partners with operations, maintenance, electrical, mechanical, controls, reliability, and equipment manufacturers to support safe operation and prevent unplanned outages.
Responsibilities
Key Responsibilities
- Develop and manage condition monitoring programs, asset criticality assessments, inspection routes, monitoring frequencies, baseline measurements, return-to-service activities by establishing baselines and identifying equipment health indicators abnormal equipment behavior for generation and utility substation assets.
- Perform vibration analysis using spectra, time waveforms, phase, envelope analysis, and operating trends to identify imbalance, misalignment, looseness, bearing defects, and other rotating-equipment faults.
- Lead condition monitoring programs for power generation and utility substation assets, establish monitoring priorities, baselines, alarm thresholds, and escalation criteria.
- Monitor gas turbines, diesel and natural-gas reciprocating generators, alternators, and auxiliary equipment using vibration analysis, thermography, lubricant analysis, ultrasound, and operating trends to identify deterioration and developing faults.
- Assess utility substation equipment, including transformers, bushings, circuit breakers, switchgear, and cables, using thermal surveys, oil and dissolved gas analysis, and applicable electrical diagnostic results.
- Interpret transformers dissolved gas analysis, oil quality, moisture, temperature, cooling-system performance, and bushing and tap-changer condition; correlate trends with loading, operating history, and laboratory findings.
- Conduct infrared thermography and ultrasound surveys; assess partial-discharge data where applicable, breaker operating times and contact resistance, insulating-medium condition, and insulation test results with electrical testing specialists.
- Establish and periodically review condition baselines, alarm thresholds, diagnostic rules, and escalation criteria using manufacturer guidance, operating context, equipment history, and applicable standards; coordinate changes through approved controls.
- Analyze alarms and abnormal trends, confirm data validity, assess fault severity and progression, and issue actionable recommendations with urgency, operating implications, inspection needs, and maintenance priorities.
- Translate findings into maintenance work orders, outage scopes, repair and replacement recommendations, and asset-life assessments; track actions to closure and confirm equipment condition after maintenance.
- Support commissioning, acceptance testing, startup and shutdown monitoring, load testing, and return-to-service activities by establishing baselines and identifying abnormal equipment behavior.
- Maintain diagnostic reports, asset health dashboards, inspection records, and computerized maintenance management system data; report defect detection, monitoring coverage, action closure, and reliability improvement, and train site personnel.
Required Qualifications
- Bachelor's degree in Mechanical Engineering, Condition Monitoring, Electromechanical Engineering, Instrumentation Engineering, or a related technical discipline.
- 6-10+ years of relevant experience in power plant condition monitoring, predictive maintenance, or equipment diagnostics, including practical monitoring of gas turbines and diesel and natural-gas reciprocating generators.
- Demonstrated ability to perform condition monitoring of utility substation equipment, including transformers, circuit breakers, switchgear, bushings, cables, and associated auxiliary systems.
- Strong practical competence in vibration data collection and analysis, infrared thermography, lubricant analysis, ultrasound, and interpretation of operating and performance trends.
- Advanced technical expertise in interpreting transformer dissolved gas and insulating-oil analyses, electrical insulation diagnostics, partial-discharge measurements, and circuit-breaker condition indicators; demonstrated ability to correlate diagnostic results, identify developing failure modes, assess fault severity, and define appropriate specialist testing and corrective actions.
- High proficiency in configuring and using Bently Nevada and other condition monitoring software applications for data acquisition, advanced vibration diagnostics, trend analysis, alarm configuration, and equipment health reporting; strong hands-on competence with portable and online monitoring systems, plant historians, and maintenance management systems, including measurement validation, data integration, and reliable asset record management.
- Ability to interpret equipment drawings, single-line diagrams, P&IDs, manufacturer manuals, test reports, and maintenance history, and relate diagnostic findings to equipment failure modes.
- Strong fault diagnosis, root-cause analysis, technical reporting, and communication skills, with the ability to prioritize equipment risks and coordinate corrective actions across operations, maintenance, and manufacturers.
• Ability to work safely in operating power plants and substations and support site surveys, planned outages, maintenance windows, and urgent equipment assessments as operational needs require.
Preferred Qualifications
- Recognized vibration analyst certification at Category II or above, with Category III preferred; relevant thermography, ultrasound, or machinery lubrication and oil-analysis certification.
- Experience with advanced gas turbine and reciprocating-engine diagnostics, generator electrical condition assessment, borescope findings, and correlation of multiple diagnostic techniques.
- Experience with online transformer monitoring, bushing and partial-discharge monitoring, breaker diagnostics, substation asset health indexing, and risk-based maintenance planning.
#LI-SB36
Qualifications
Minimum Job QualificationsEducation and/or Experience:
11 years of experience in software engineering, infrastructure management, or related field
OR
Bachelor's Degree in Computer Science, Engineering, or related field AND 7 years of experience in software engineering, infrastructure management, or related field
OR
Master's Degree in Computer Science, Engineering, or related field AND 5 years of experience in software engineering, infrastructure management, or related field
OR
Doctorate in Computer Science, Engineering, or related field AND 3 year of experience in software engineering, infrastructure management, or related field.
Job Skills:
Same skills as prior level plus;
Incident Management and Response Demonstrated ability in or knowledge of incident management and response, including timely handling and escalation of incidents to minimize business impact.
Troubleshooting Demonstrated ability in or knowledge of troubleshooting, including diagnosing and resolving issues across various technical domains.
Virtualization Demonstrated ability in or knowledge of virtualization, including designing, managing, or troubleshooting virtual environments and infrastructure.
Security Tools Demonstrated ability in or knowledge of security tools, including leveraging technology to improve and maintain organizational security.
Database Reliability Support Demonstrated experience supporting and troubleshooting databases, applying SRE best practices for reliability and recovery.
Automation Experience:
5 years of experience in automation.
Programming Experience:
5 years of experience in programming and/or scripting.
Preferred Job Qualifications
Education and/or Experience:
11 years of experience in software engineering, infrastructure management, or related field
OR
Bachelor's Degree in Computer Science, Engineering, or related field AND 7 years of experience in software engineering, infrastructure management, or related field
OR
Master's Degree in Computer Science, Engineering, or related field AND 5 years of experience in software engineering, infrastructure management, or related field
OR
Doctorate in Computer Science, Engineering, or related field AND 3 years of experience in software engineering, infrastructure management, or related field.
Automation Experience:
7 years of experience in automation.
Programming Experience:
7 years of experience in programming and/or scripting.
Hyperscale cloud infrastructure (OCI), autonomous database, enterprise ERP/HCM, and healthcare AI software leader.
- Headquarters
- United States
- Open roles
- 419 live on perfectrole
- Website
- oracle.com
- Visa sponsor
- Licensed sponsor
- Hires through
- Oracle HCM
Workplace policy: Remote & Hybrid across Austin, Redwood Shores, Seattle, London, Zurich, and Global Hubs
All Oracle roles